FEATURES:
â—Capacity: 5-100klb
â—Alloy Steel, stainless steel
Â
APPLICATION:
â—Hopper scale
Â
Â
Outline Dimension |
||||||||
Rated capacity |
L |
L1 |
L2 |
D |
D1 |
D2 |
H |
H1 |
5~10klb |
206.2 |
174.6 |
133.1 |
43.2 |
37.6 |
16.8 |
28.5 |
12.7 |
20~25klb |
206.2 |
174.6 |
133.1 |
49.5 |
37.6 |
16.8 |
28.5 |
12.7 |
30~75klb |
260 |
216 |
164 |
76 |
69.3 |
27 |
60 |
25.4 |
100klb |
285.8 |
241.3 |
190 |
88.9 |
82.3 |
27 |
63.5 |
38.1 |
Â
SPECIFICATION
Rated capacity: 5-100klb
Rated output:3.0±0.003mv/v
Accuracy class: 0.05
Non-repeatability: ±0.02% F.S
Non-linearity: ±0.05% F.S
Hysteresis error: ±0.05% F.S
Zero balance: ±1% F.S
Creep error(30minutes): ±0.02% F.S
Temperature effect on zero: ±0.02% F.S
Temperature effect on output: ±0.02% F.S
Compensated temperature range: -10 ~ +40℃
Operating temperature range: -30 ~ +70℃
Maximum safe overload: 150% OF R.C
Ultimate safe overload: 200% OF R.C
Recommended Excitation: 10 ~ 12V DC
Maximum Excitation: 15V DC
Environment protection: IP68
Input impedance: 750±10Ω
Output impedance: 702±5Ω
Insulation resistance at 50V DC: ≥5000MΩ
Material: nickel-plated alloy steel
Cable : length 8m, diameter 5mm(5-10klb); length 12m, diameter 6mm(20-75klb);length 16m diameter 6mm(100klb)
Â